How to operate new and old air compressor? In order to meet the market needs, factories make diferent manufacturing plans so the using compressed air need is also various. Beside, Factories often have backup machine( which is for little use) or or companies with seasonal production characteristics, air compressors operate seasonally. For many years of repair and maintenance Air compressors, air dryers we have a lot of trouble cases such as: the machine cannot start, the machine starts up with load is immediately stopped, when the machine is turned on, the contactor is fired .... One of the causes of the problem is air compressors is not used for a long time, leading to moisture of electrical equipments and oil filter, separator ... To help customers minimize the problems we would like to sumerize some notes when operating air compressors which is not used for a long time and the operation for newly air compressors.

1. Operation - Notes : + Before turn the power ON, make sure if 1- Installation 2- Piping 3- Electrical wiring have been properly completed. + After the installation or after long unused time ( over a week) , run the machine by way off innitial start-up. 2. Before power on
- Notes : Oil level lowers after starting. 3. Power on
Notes : For safey ,the unit will not operate for 5 seconds after the power is ON, even START button is pressed + Make sure stability between about 65 and 100 + Make sure that, about 20 minutes after starting , the refrigent pressure gauge reads 0,41 to 0,73 MPa. 0.73Mpa. + Make sure that about 20 minutes after starting the automatic condensate trap start draining the condensate. 5. Stop
|