Sung Shin - VSD air compressor

Monday - 18/02/2019 10:54
 Variable Frequency Driver (VFD) -reducing energy consumpsion system is produced with the required amount of air   and compressor shutdown under no-load conditions. In order to minimize unnecessary energy loss through the inverter to adjust the number spin of compressor .Energy consumption saving arises starting by reducing the starting current as the inverter is operated.
may nen khi sung shin vsd,may nen khi shung shin dong VSD, bao duong may nen khi sung shin
Sung Shin FORT100 - VSD air compressor

1. Outsanding funtions of Sung shin air compressor.
- Simple and convenient  maintenance, repair from all directions.
- Oil separator: 4-level oil separating system minimizes the amount of oil mixed in the discharge gas.
- Intakes air: Improve the quality and longevity of air compressors, reduce the  machine noise  when idling.
- Air end : Using GHH - Germany air end , the company specializes in supplying Atlas Copco and Ingersoll Rand compressors, Sung Shin air compressors with high durability, efficient  and stable operation in harsh environment shall satisfy your requirements.
2. Features:
- Direct drive.
- 1: 1 transmission ratio optimizes the performance of the engine.
- Reduce maintenance  and machine operating costs.
3. Specifications:
 
MODEL FORT 30 FORT 50
  Motor power HP (kW) 30 (22) 50 (37)
  F.A.D (m3/min) 7 barg 3,78 6,65
  F.A.D (m3/min) 9 barg 3,41 5,69
  Discharge connection 1” 1-1/4”
  Type of drive Direct  Indirect 
  Cooling method Air cooled  Air cooled 
  Starting method Y/∆ or inverter Y/∆ or inverter
  Dimension (mm) Length 1300 1400
  Dimension(mm) Depth 880 930
  Dimension (mm) Height  1245 1365
  Weight (kg) 580 920

4.Variable frequency driver (VFD)-reducing energy consumpsion system is produced with the required amount of air   and compressor shutdown under idling condition.
may nen khi sung shin su dung bien tan vsd,Sung shin air compressor, bao duong may nen khi truc vit sung shin, sửa chữa máy nén khí sung shin, phụ tùng máy nén khí sung shin, máy nén khí trục vit sung shin, may nen khi sung shin han quoc,

In order to minimize unnecessary energy loss through the inverter to adjust the number of spin of compressor.Energy consumption saving arises starting by reducing the starting current as the inverter is operated.
In most factories, compressors account for about 70% of the total power consumption to produce compressed air. The demand for compressors in the factory varies depending on many factors such as time, seasons, weather, working environment, etc... and depending on the influence of the factors, the compressed air output of the compressor is also different. Therefore, air compressors repeat the operation process with extra load and no load depending on the demand, this process takes much more unnecessary energy than we think.
5.
The cases which  FORT-VSD   have a high use value
- In case of repeated loading / unloading process
- When the air consumption model has big changes
- The no-load operation lasts for long time
- Capacity of receiving equipment is small
- Maintaining small pressure fluctuations is small
Sung Shin air compressor - VSD,VSD  inverter  used air compressor, air compressor, how to install air compressor, repair sungshin air compressor, Sungshin air compressor parts, Sungshin screw air compressor, Sungshin air compressor.

Total notes of this article: 6 in 2 rating

Ranking: 3 - 2 vote
Click on stars to rate this article