Troubleshooting of Handsome II

Wednesday - 31/07/2019 03:17

  Step 1: Check the condition of the LED lamps and find out the cause of      emergency shutdown by refering to the table below:

RUNNING lamp FAULT
  lamp
Fault detected  Operation of compressor
OFF  ON Compressor motor overcurrent or motor coil high temperature. Emergency shutdown.
OFF Blinking
(1.2 sec./cycle)
Discharge temperature higher than 110ºC(230ºF) or sensor short circuit.
OFF High pitched blinking.
(0,4 sec./cycle)
Sensor failure or poor connector contact.
BLINKING  ON  Dryer failure. Emergency shutdown unless the conditiuous operation is selected.

  Step 2: Eliminate  the cause of the fault.
  Step 3: Press the START button (green) to restart and the FAULT lamp will go  out.
  Caution:
  • The dryer safety machanism is activated when the START and STOP buttons are pressed frequently.
  • Keep 3 minute interval between stop and restart.
  • Countermeasure for motor overcurrent/ motor coil high temperature.
                                                                                            Meter panel:
LED lamps on the meter panel Reset
Power  Running Fault Reset thermal relay
  1.  When excessive curent passed in the motor, the thermal switch trips and the compressor shuts down. Remove the cause of overcurrent and press the thermal relay reset (blue) button. The lamp will go out when the START button (green) is pressed to restart.
  1. Reduced  cooling air volume for the motor may increase motor temperature, activating the motor protector and stopping the compressor. Eliminate the cause, i.e clogged dust filter or the like. Press the START button ( green) to restart, and the FAULT lamp will go out.

When the motor does not starts.
Step 1:  Turn off the earth leakage breaker.
Step 2:  Interchange two of the three phases in the power unit and connect again.
 Step 3:  Return the breaker on and see if the motor starts.

 